UV Energy Meter Technical Parameters

Understanding the technical parameters of UV energy meters is crucial for proper selection and use of the instrument. The following are detailed explanations of the main technical parameters.

Measurement Range

Spectral Range: 250-410nm (covers UVA, UVB, UVC full spectrum)

Energy Range: 0-999999 mJ/cm²

Intensity Range: 0-9999 mW/cm²

Accuracy Indicators

Measurement Accuracy: ±5% (under standard conditions)

Repeatability: ±2%

Linearity: ±3%

Temperature Coefficient: ±0.1%/℃

Physical Parameters

Dimensions: Diameter 90mm × Thickness 12mm

Weight: Approximately 150g

Housing Material: Aluminum alloy/Stainless steel

Operating Temperature: -10℃ to 70℃

Power Parameters

Power Type: 3.6V lithium battery

Battery Life: Approximately 10000 hours

Power Consumption: 100μA (standby mode)

Charging Method: Dedicated charger

UV Energy Meter Usage Instructions

Proper use of UV energy meters is key to ensuring measurement accuracy. Please follow these steps:

Power On Preparation

  • Check if battery power is sufficient
  • Ensure instrument surface is clean and contamination-free
  • Confirm measurement environment temperature is within allowable range
  • Check if the instrument has been calibrated

Measurement Operation

  • Turn ON switch, LCD display shows zero
  • Place UV energy meter near UV lamp source
  • Ensure instrument back (sensor side) faces the light source
  • Set appropriate exposure time according to process requirements
  • Read measurement value on display screen

Precautions

  • Do not look directly or indirectly at UV light source
  • Avoid any body parts being directly exposed to UV light
  • Instrument can withstand high temperatures, but not exceeding 10 seconds on conveyor belt
  • Maximum temperature resistance 110℃, but recommended working temperature not exceeding 70℃
  • Turn off power promptly after measurement

Data Recording

  • Record measurement date, time and ambient temperature
  • Record UV lamp type and power
  • Record measurement position and distance
  • Perform regular data backup and analysis
  • Establish measurement data archive

UV Energy Meter Calibration Methods

Regular calibration is key to ensuring UV energy meter measurement accuracy. We provide professional calibration services and method guidance.

Calibration Cycle

Recommended Calibration Cycle: 12 months

Frequent Use: 6 months

Critical Applications: 3 months

After Instrument Repair: Must be recalibrated

Calibration Standards

Reference Standard: National metrology standards

Calibration Institutions: Authorized institutions like NIM

Calibration Certificate: Provide authoritative calibration report

Traceability: Traceable to national standards

On-site Calibration

  • Use standard UV light source for comparison
  • Check instrument zero drift
  • Verify measurement linearity
  • Confirm temperature compensation function
  • Record calibration data

Calibration Services

  • Provide on-site calibration services
  • Mail-in calibration services
  • Calibration certificate issuance
  • Calibration data archiving
  • Calibration cycle reminders

UV Energy Meter Maintenance Guidelines

Proper maintenance can extend the service life of UV energy meters and ensure measurement accuracy.

Daily Maintenance

  • Regularly clean instrument surface
  • Check battery power
  • Verify instrument functions properly
  • Record usage conditions
  • Store instrument properly

Sensor Maintenance

  • Avoid sensor contamination
  • Regularly check sensor sensitivity
  • Prevent mechanical damage to sensor
  • Avoid direct strong light exposure to sensor
  • Regular sensor calibration

Battery Maintenance

  • Regularly check battery voltage
  • Avoid over-discharge
  • Use original charger
  • Remove battery when not in use for long periods
  • Pay attention to battery replacement cycle

Troubleshooting

  • Display not lit: Check battery
  • Abnormal measurement values: Recalibrate
  • Instrument not responding: Restart instrument
  • Data loss: Check storage
  • Other issues: Contact technical support

UV-int Energy Meter Model Comparison

According to different application requirements, we provide various models of UV energy meters for your selection.

UV-Int150

Standard UV Energy Meter

Industry Standard

Designed in 2004, standard measurement tool for UV curing industry

UV-Int140

UV Energy Meter + UV Light Warning

Innovative Design

Safety warning function, suitable for hazardous environments

UV-Int159

UV Energy + UV Intensity + Temperature Measurement

Multi-functional

Suitable for multi-parameter measurement in complex process environments

UV-Int160

UV Energy + UV Intensity + Temperature + USB Connection

High Performance

With data recording and curve analysis functions

Professional Technical Consultation

Professional Selection Guidance

If you are unsure which UV energy meter is most suitable for your production line or experimental needs, our technical team will provide professional selection advice and technical support.

Online Consultation View FAQ

Professional Technical Support

+86 133 0651 2129

Professional team provides UV testing solutions, technical consultation and after-sales service

View Complete Product Catalog
UV-DESIGN

UV-integrator
Designed & Manufactured by UV-int

UV-int QR Code

Scan QR code to visit official website